How to change Firmware settings for a specific region or Vendor for Telit modules?
Question
I use a Telit module and want to be able to use my module in a specific region in the world. Is there a way to change the settings automatically depending on vendor or region for the application?
Solution
Telit modules do have an AT command that allows you to change the Firmware Image for your desired region or network provider.
The command AT#FWSWITCH allows you to set the Active firmware image.
The Telit modules that currently have this AT command available
Telit LE910Cx
Cinterion MV32-W
Telit LN920 Family
Telit FN980 Family
Telit LM940 Family
Telit FN920C04 Family
ME910C1
FN990 Family
Example given:
I have an application with Telit FN990A40 that I want to use in the US with the operator AT&T, and then how do I change to the correct Firmware Image?
Start up with locating the AT command guide (check out our webpage for the latest AT command guide), and locate the command FWSWITCH and the searched for Firmware Image.
Then, depending on what OS you are working with, you can either use a terminal program like YAT or TerraTerm in Windows or Minicom or a similar program for Linux.
Send the command
AT#FWSWITCH=10
Let the modem reboot, or if the modem doesn't reboot itself, send
AT#REBOOT